Review




Structured Review

FineTest Biotech Inc human il-26 elisa kit
Details of the kits used for the detection of soluble factors in co-culture supernatants.
Human Il 26 Elisa Kit, supplied by FineTest Biotech Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/human il-26 elisa kit/product/FineTest Biotech Inc
Average 90 stars, based on 1 article reviews
human il-26 elisa kit - by Bioz Stars, 2026-02
90/100 stars

Images

1) Product Images from "Adipose-Derived Mesenchymal Stem Cells from Arthritis Patients: Differential Modulation of CD4 + T Cell Activation and Cytokine Production"

Article Title: Adipose-Derived Mesenchymal Stem Cells from Arthritis Patients: Differential Modulation of CD4 + T Cell Activation and Cytokine Production

Journal: Medical Science Monitor: International Medical Journal of Experimental and Clinical Research

doi: 10.12659/MSM.945273

Details of the kits used for the detection of soluble factors in co-culture supernatants.
Figure Legend Snippet: Details of the kits used for the detection of soluble factors in co-culture supernatants.

Techniques Used: Enzyme-linked Immunosorbent Assay



Similar Products

86
Thermo Fisher human il 26 elisa kit
Serum cytokine concentrations in allergen-sensitized subjects vs. controls. <t>IL-26</t> ( A ) and IL-17 A ( B ) serum concentrations were measured by ELISA in both non-allergen-sensitized and allergen-sensitized study subjects ( n = 17 and n = 60, respectively). Statistical significance was assessed using the Mann-Whitney test. Error bars represent mean ± SEM. Dashed horizonal line represents the lower limit of detection of the ELISA assay
Human Il 26 Elisa Kit, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/human il 26 elisa kit/product/Thermo Fisher
Average 86 stars, based on 1 article reviews
human il 26 elisa kit - by Bioz Stars, 2026-02
86/100 stars
  Buy from Supplier

90
FineTest Biotech Inc human il-26 elisa kit
Details of the kits used for the detection of soluble factors in co-culture supernatants.
Human Il 26 Elisa Kit, supplied by FineTest Biotech Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/human il-26 elisa kit/product/FineTest Biotech Inc
Average 90 stars, based on 1 article reviews
human il-26 elisa kit - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

90
Cusabio human il-26 elisa kit
Details of the kits used for the detection of soluble factors in co-culture supernatants.
Human Il 26 Elisa Kit, supplied by Cusabio, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/human il-26 elisa kit/product/Cusabio
Average 90 stars, based on 1 article reviews
human il-26 elisa kit - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

92
Cusabio human il 26 elisa kit
Details of the kits used for the detection of soluble factors in co-culture supernatants.
Human Il 26 Elisa Kit, supplied by Cusabio, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/human il 26 elisa kit/product/Cusabio
Average 92 stars, based on 1 article reviews
human il 26 elisa kit - by Bioz Stars, 2026-02
92/100 stars
  Buy from Supplier

92
Cusabio il 26 elisa kit
Details of the kits used for the detection of soluble factors in co-culture supernatants.
Il 26 Elisa Kit, supplied by Cusabio, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/il 26 elisa kit/product/Cusabio
Average 92 stars, based on 1 article reviews
il 26 elisa kit - by Bioz Stars, 2026-02
92/100 stars
  Buy from Supplier

92
Cusabio elisa
Details of the kits used for the detection of soluble factors in co-culture supernatants.
Elisa, supplied by Cusabio, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/elisa/product/Cusabio
Average 92 stars, based on 1 article reviews
elisa - by Bioz Stars, 2026-02
92/100 stars
  Buy from Supplier

Image Search Results


Serum cytokine concentrations in allergen-sensitized subjects vs. controls. IL-26 ( A ) and IL-17 A ( B ) serum concentrations were measured by ELISA in both non-allergen-sensitized and allergen-sensitized study subjects ( n = 17 and n = 60, respectively). Statistical significance was assessed using the Mann-Whitney test. Error bars represent mean ± SEM. Dashed horizonal line represents the lower limit of detection of the ELISA assay

Journal: Respiratory Research

Article Title: Systemic IL-26 correlates with improved asthma control in children sensitized to dog allergen

doi: 10.1186/s12931-024-02773-7

Figure Lengend Snippet: Serum cytokine concentrations in allergen-sensitized subjects vs. controls. IL-26 ( A ) and IL-17 A ( B ) serum concentrations were measured by ELISA in both non-allergen-sensitized and allergen-sensitized study subjects ( n = 17 and n = 60, respectively). Statistical significance was assessed using the Mann-Whitney test. Error bars represent mean ± SEM. Dashed horizonal line represents the lower limit of detection of the ELISA assay

Article Snippet: IL-26 was measured from serum using the Human IL-26 ELISA kit from Invitrogen (Carlsbad, CA, USA), which has an assay range between 3.3 and 800 pg/mL.

Techniques: Enzyme-linked Immunosorbent Assay, MANN-WHITNEY

Serum cytokine concentrations in subjects with and without asthma. Serum concentrations of IL-26 ( A ) and IL-17 A ( B ) were measured by ELISA in both non-allergen-sensitized and allergen-sensitized study subjects ( n = 17 and n = 60, respectively). Comparisons were made in subjects with or without asthma. Statistical significance was assessed using the Kruskal-Wallis test for multiple comparisons. Error bars represent mean ± SEM. Dashed horizonal line represents the lower limit of detection of the ELISA assay

Journal: Respiratory Research

Article Title: Systemic IL-26 correlates with improved asthma control in children sensitized to dog allergen

doi: 10.1186/s12931-024-02773-7

Figure Lengend Snippet: Serum cytokine concentrations in subjects with and without asthma. Serum concentrations of IL-26 ( A ) and IL-17 A ( B ) were measured by ELISA in both non-allergen-sensitized and allergen-sensitized study subjects ( n = 17 and n = 60, respectively). Comparisons were made in subjects with or without asthma. Statistical significance was assessed using the Kruskal-Wallis test for multiple comparisons. Error bars represent mean ± SEM. Dashed horizonal line represents the lower limit of detection of the ELISA assay

Article Snippet: IL-26 was measured from serum using the Human IL-26 ELISA kit from Invitrogen (Carlsbad, CA, USA), which has an assay range between 3.3 and 800 pg/mL.

Techniques: Enzyme-linked Immunosorbent Assay

Serum cytokine concentrations in subjects with and without eczema. Serum concentrations of IL-26 ( A ) and IL-17 A ( B ) were measured by ELISA in both non-allergen-sensitized and allergen-sensitized study subjects ( n = 17 and n = 60, respectively). Comparisons were made in subjects with or without eczema. Statistical significance was assessed using the Kruskal-Wallis test for multiple comparisons. Error bars represent mean ± SEM. Dashed horizonal line represents the lower limit of detection of the ELISA assay

Journal: Respiratory Research

Article Title: Systemic IL-26 correlates with improved asthma control in children sensitized to dog allergen

doi: 10.1186/s12931-024-02773-7

Figure Lengend Snippet: Serum cytokine concentrations in subjects with and without eczema. Serum concentrations of IL-26 ( A ) and IL-17 A ( B ) were measured by ELISA in both non-allergen-sensitized and allergen-sensitized study subjects ( n = 17 and n = 60, respectively). Comparisons were made in subjects with or without eczema. Statistical significance was assessed using the Kruskal-Wallis test for multiple comparisons. Error bars represent mean ± SEM. Dashed horizonal line represents the lower limit of detection of the ELISA assay

Article Snippet: IL-26 was measured from serum using the Human IL-26 ELISA kit from Invitrogen (Carlsbad, CA, USA), which has an assay range between 3.3 and 800 pg/mL.

Techniques: Enzyme-linked Immunosorbent Assay

Serum cytokine concentrations in subjects with and without allergic rhinitis. Serum concentrations of IL-26 ( A ) and IL-17 A ( B ) were measured by ELISA in both non-allergen-sensitized and allergen-sensitized study subjects ( n = 17 and n = 60, respectively). Comparisons were made in subjects with or without allergic rhinitis. Statistical significance was assessed using the Kruskal-Wallis test for multiple comparisons. Error bars represent mean ± SEM. Dashed horizonal line represents the lower limit of detection of the ELISA assay

Journal: Respiratory Research

Article Title: Systemic IL-26 correlates with improved asthma control in children sensitized to dog allergen

doi: 10.1186/s12931-024-02773-7

Figure Lengend Snippet: Serum cytokine concentrations in subjects with and without allergic rhinitis. Serum concentrations of IL-26 ( A ) and IL-17 A ( B ) were measured by ELISA in both non-allergen-sensitized and allergen-sensitized study subjects ( n = 17 and n = 60, respectively). Comparisons were made in subjects with or without allergic rhinitis. Statistical significance was assessed using the Kruskal-Wallis test for multiple comparisons. Error bars represent mean ± SEM. Dashed horizonal line represents the lower limit of detection of the ELISA assay

Article Snippet: IL-26 was measured from serum using the Human IL-26 ELISA kit from Invitrogen (Carlsbad, CA, USA), which has an assay range between 3.3 and 800 pg/mL.

Techniques: Enzyme-linked Immunosorbent Assay

Serum cytokine concentrations in subjects with and without food allergies. Serum concentrations of IL-26 ( A ) and IL-17 A ( B ) were measured by ELISA in both non-allergen-sensitized and allergen-sensitized study subjects ( n = 17 and n = 60, respectively). Comparisons were made in subjects with or without a self-reported history of one or more food allergies. Statistical significance was assessed using the Kruskal-Wallis test for multiple comparisons. Error bars represent mean ± SEM. Dashed horizonal line represents the lower limit of detection of the ELISA assay

Journal: Respiratory Research

Article Title: Systemic IL-26 correlates with improved asthma control in children sensitized to dog allergen

doi: 10.1186/s12931-024-02773-7

Figure Lengend Snippet: Serum cytokine concentrations in subjects with and without food allergies. Serum concentrations of IL-26 ( A ) and IL-17 A ( B ) were measured by ELISA in both non-allergen-sensitized and allergen-sensitized study subjects ( n = 17 and n = 60, respectively). Comparisons were made in subjects with or without a self-reported history of one or more food allergies. Statistical significance was assessed using the Kruskal-Wallis test for multiple comparisons. Error bars represent mean ± SEM. Dashed horizonal line represents the lower limit of detection of the ELISA assay

Article Snippet: IL-26 was measured from serum using the Human IL-26 ELISA kit from Invitrogen (Carlsbad, CA, USA), which has an assay range between 3.3 and 800 pg/mL.

Techniques: Enzyme-linked Immunosorbent Assay

Serum IL-26 concentrations correlate with serum IL-17 A in allergen-sensitized subjects. Serum concentrations of IL-26 and IL-17 A were measured by ELISA in allergen-sensitized subjects. Concentrations of each cytokine were plotted relative to each other for ( A ) all allergen-sensitized subjects ( n = 60) or ( B ) limited to only allergen-sensitized subjects with asthma ( n = 51). Statistical significance was assessed using the Spearman correlation coefficient

Journal: Respiratory Research

Article Title: Systemic IL-26 correlates with improved asthma control in children sensitized to dog allergen

doi: 10.1186/s12931-024-02773-7

Figure Lengend Snippet: Serum IL-26 concentrations correlate with serum IL-17 A in allergen-sensitized subjects. Serum concentrations of IL-26 and IL-17 A were measured by ELISA in allergen-sensitized subjects. Concentrations of each cytokine were plotted relative to each other for ( A ) all allergen-sensitized subjects ( n = 60) or ( B ) limited to only allergen-sensitized subjects with asthma ( n = 51). Statistical significance was assessed using the Spearman correlation coefficient

Article Snippet: IL-26 was measured from serum using the Human IL-26 ELISA kit from Invitrogen (Carlsbad, CA, USA), which has an assay range between 3.3 and 800 pg/mL.

Techniques: Enzyme-linked Immunosorbent Assay

Serum IL-26 concentrations correlate with Asthma Control Test (ACT) Score in allergen-sensitized subjects. Serum concentrations of IL-26 were measured by ELISA in allergen-sensitized subjects with asthma ( n = 51) and plotted relative to ACT scores. Statistical significance was assessed using the Spearman correlation coefficient

Journal: Respiratory Research

Article Title: Systemic IL-26 correlates with improved asthma control in children sensitized to dog allergen

doi: 10.1186/s12931-024-02773-7

Figure Lengend Snippet: Serum IL-26 concentrations correlate with Asthma Control Test (ACT) Score in allergen-sensitized subjects. Serum concentrations of IL-26 were measured by ELISA in allergen-sensitized subjects with asthma ( n = 51) and plotted relative to ACT scores. Statistical significance was assessed using the Spearman correlation coefficient

Article Snippet: IL-26 was measured from serum using the Human IL-26 ELISA kit from Invitrogen (Carlsbad, CA, USA), which has an assay range between 3.3 and 800 pg/mL.

Techniques: Enzyme-linked Immunosorbent Assay

Increasing serum IL-26 concentrations correlate with surrogate markers of asthma severity in allergen-sensitized subjects. Serum concentrations of IL-26 were measured by ELISA in allergen-sensitized subjects with asthma ( n = 51). ( A ) IL-26 concentrations were plotted relative to each subject’s daily inhaled corticosteroid dose. Statistical significance was assessed using the Spearman correlation coefficient. ( B ) IL-26 concentrations were compared between subjects who had no prior hospitalizations vs. one or more hospitalizations for asthma in the 12 months preceding study enrolment. ( C ) IL-26 concentrations were compared between subjects who had received no oral steroid vs. those receiving one or more courses of oral steroids in the 12 months preceding study enrolment. ( B - C ) Statistical significance was assessed using the Mann-Whitney test. Error bars represent mean ± SEM. Dashed horizonal line represents the lower limit of detection of the ELISA assay

Journal: Respiratory Research

Article Title: Systemic IL-26 correlates with improved asthma control in children sensitized to dog allergen

doi: 10.1186/s12931-024-02773-7

Figure Lengend Snippet: Increasing serum IL-26 concentrations correlate with surrogate markers of asthma severity in allergen-sensitized subjects. Serum concentrations of IL-26 were measured by ELISA in allergen-sensitized subjects with asthma ( n = 51). ( A ) IL-26 concentrations were plotted relative to each subject’s daily inhaled corticosteroid dose. Statistical significance was assessed using the Spearman correlation coefficient. ( B ) IL-26 concentrations were compared between subjects who had no prior hospitalizations vs. one or more hospitalizations for asthma in the 12 months preceding study enrolment. ( C ) IL-26 concentrations were compared between subjects who had received no oral steroid vs. those receiving one or more courses of oral steroids in the 12 months preceding study enrolment. ( B - C ) Statistical significance was assessed using the Mann-Whitney test. Error bars represent mean ± SEM. Dashed horizonal line represents the lower limit of detection of the ELISA assay

Article Snippet: IL-26 was measured from serum using the Human IL-26 ELISA kit from Invitrogen (Carlsbad, CA, USA), which has an assay range between 3.3 and 800 pg/mL.

Techniques: Enzyme-linked Immunosorbent Assay, MANN-WHITNEY

Details of the kits used for the detection of soluble factors in co-culture supernatants.

Journal: Medical Science Monitor: International Medical Journal of Experimental and Clinical Research

Article Title: Adipose-Derived Mesenchymal Stem Cells from Arthritis Patients: Differential Modulation of CD4 + T Cell Activation and Cytokine Production

doi: 10.12659/MSM.945273

Figure Lengend Snippet: Details of the kits used for the detection of soluble factors in co-culture supernatants.

Article Snippet: IL-26 , Human IL-26 ELISA Kit , FineTest , 15.625–1000 pg/ml.

Techniques: Enzyme-linked Immunosorbent Assay